Software RTU  
 
 


Controles develops different software modules for the RTU587. This modules make possible several functions such as: console and data base, system administration, communications, acquisition, edition and execution of PLC routines, synchronization through GPS, protocol convertion IRIG-B.

 
 
 
 
     
 

Software for the RTU587

Basic software

 


   
- Console and data base module, MCONRQ 34 kb
- System aministration module RTURQ, PRCMRQ 34 kb
   
Slave communication modules    
- Slave communication module IEC 60870-5-101 and 104, MC101RQ 34 kb
- Slave communication module DNP 3.0, MCDNPRQ 43 kb
- Slave communication module Modbus, MCMODRQ 36 kb
     
Master communication module    
- I/O a cquisition module with internal bus, MA485RQ 32 kb
- Master acquisition module Modbus, MAMODRQ 36 kb
- Master acquisition module IEC 60870-5-101 and 104, MA101RQ 34 kb
- Master acquisition module for protection relays, MARPROTRQ 34 kb
- Master acquisition module DNP 3.0, MADNPRQ 43 kb
     
Runtime PLC module
   
- Edition and execution of PLC routines, MSPLCRQ 276 kb
     
Time synchronization module
   
- Synchronization module with GPS, MGPSRQ 43 kb
 
 
 
 
 

Console and data base module, MCONRQ

Brochure
34 kb  

Console module: central module of supervision / administration of the system.
Data base module: module that administrate the real time data base with the state of the I/O points of the system.

 
 
 
 
 

RTURQ system administration module, PRCMRQ

Brochure
34 kb  

Program that allows the configuration of the different modules of the RTU, and also the supervision and administration of the system.
The program runs in an external PC with Windows NT or Windows 2000. It communicates with the console module of the RTU through a serial link or TCP/IP.

 
 
 
     
 

Slave communication module IEC 60870-5-101 and 104, MC101RQ

Brochure
 34 kb  

Communicates with a control center through the IEC 870-5 protocol in its application profile 101 (optionally 104).
Communications:
RS232, RS422 or RS485 for IEC 870-5-101
TCP/IP for IEC 870-5-104
Baud rate: 300, 600, 1200, 2400, 4800, 9600, 14400 y 19200 bps.

 
 
 
 
 

Slave communication module DNP 3.0, MCDNPRQ

Brochure 43 kb  

Function: Communicates with a control centel through the DNP 3.00 protocol.
Communications: serials RS232, RS422 ,RS485 of fiber optic depending on the used interface.
Baud rate: 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200 bps.

 
 
 
 
 

Slave communication module MODBUS, MCMODRQ

Brochure
36 kb  

Function: Communicates with a control center through Modbus protocol.
Communications: For Modbus ASCII or Modbus RTU: serials RS232, RS422 or RS485 serial encapsuled in UDP. For Modbus TCP ethernet network.
Baud rate: 300, 600, 1200, 2400, 4800, 9600, 14400 y 19200 bps.

 
 
 
 
 

I/O acquisition module with internal bus, MA485RQ

Brochure
32 kb  

Function: Acquires and controls the data through the protocol BUS485BC. It communicates with a group of I/O devices through a serial port with this protocol.
Up to 16 devices could be connected in the same port.

 
 
 
 
 

Master acquisition module Modbus, MAMODRQ

Brochure
36 kb  

Function: Data acquisition of salve peripherics through Modbus protocol. Includes acquisition and command functionallities over the connected devices.
Communications: For Modbus ASCII or Modbus RTU: serials RS232, RS422 or RS485 serial encapsuled in UDP. For Modbus TCP ethernet network.
Baud rate: 300, 600, 1200, 2400, 4800, 9600, 14400 y 19200 bps.

 
 
 
 
 

Master acquisition module IEC 60870-5-101 and 104, MA101RQ

Brochure
34 kb  

Function: Master control over a slave RTUs group through the IEC 870-5 protocol in its application profile 101.
Communications:
RS232, RS422 or RS485 for IEC 870-5-101
TCP/IP for IEC 870-5-104
Baud rate: 300, 600, 1200, 2400, 4800, 9600, 14400 y 19200 bps.

 
 
 
 
 

Master protection relay interface module, MARPROTRQ

Brochure
34 kb  

Function: Allow the communication with a group of protection relays, obtaining this way, state information of the I/O available points in the relay and also allowing the command of the elements asociated to it.
Communications: RS232
Baud rate: 300, 600, 1200, 2400, 4800, 9600, 14400 y 19200 bps.
 
 
 
 
 

Master acquisition module for DNP 3.00 protocol, MADNPRQ

Brochure 43 kb  

Function: Master control of a slave RTUs group through DNP 3.00 protocol.
Communications: serial RS232, RS422, RS485 or fiber optic depending on the interface.
Baud rate: 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200 bps.
 
 
 
 
 

Development and runtime PLC modules, MSPLCRQ

Brochure
276 kb  

Run automatic process locally in the RTU based on the IEC 61131 standard. The routines are edited graphically, being possible to edit them in a flowchart.
The development its done in a PC with Windows.
 
 
 
 
 

GPS synchronization module, MGPSRQ

Brochure
43 kb  
Allows the synchronization of te clock of the RTU through an external source. Different origins are admitted such as, GPS receptors, IRIG generators, NTP, communications protocol with the control center, etc..
 
 
     