Battery Chargers |
|
|
|
|
| |
|
|
|
|
|
| |
Battery chargers, CA
series
- Single phase
- Float charge only, some models
include manual boost charge
- Electronic current limitation
|
|
| |
Application |
|
Model |
|
|
|
| |
|
|
|
|
|
|
|
|
| |
Specific for diesel generators and emergency lighting |
|
CA24V5A |
|
|
|
84 kb |
|
| |
|
|
|
|
|
|
|
| |
Up to
1500 VA, voltage from 24 to 110 Vdc, without instrument. |
|
CA24V10A,
20A, 30A, 50 A, CA48V5A, 10A, CA110V5A, 2.5A
|
|
|
|
42 kb |
|
| |
|
|
|
|
|
|
|
| |
Up to
1500 VA, voltage from 24 to 110 Vdc, with instrument. |
|
|
|
|
|
106 kb |
|
| |
|
|
|
|
|
|
|
| |
Up
to 1500 VA, voltage from 24 to 48 Vdc with float charge/boost charge
selector switch, instrument, alarms and protections |
|
CA24V10AA1C,
20A, 30A,
CA48V10AA1C, 20A, 30A
|
|
|
|
67 kb |
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
Battery chargers, RCP
series
- Three-phase supply
- Microprocessor based
- Charging modes: float charge and boost charge
- Electronic current limitation
|
|
| |
|
|
|
|
|
| |
Presentation RCP battery chargers series |
|
|
|
|
|
240 kb |
|
| |
RCP battery
chargers series |
|
|
|
|
|
110 kb |
|
| |
|
|
|
|
|
|
|
|
| |
Application |
|
Model |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
Up
to 1500 VA, voltage from 24 to110 Vdc |
|
RCP48V30A |
|
|
|
25 kb |
|
| |
|
|
|
|
|
|
|
|
| |
Up
to 5000 VA, voltage from 24 to 220 Vdc |
|
RCP48V60A |
|
|
|
76 kb |
|
| |
|
|
|
|
|
|
|
|
|
| |
Model 110 Vdc, 30 A nominal with alarm relay |
|
RCP110V30AA1C |
|
|
|
103 kb |
|
|
| |
|
|
|
|
|
|
|
|
|
| |
Battery charger, CHT series |
|
|
|
|
|
|
|
|
| |
CHT
series, up to 300 VA, single phase, voltages from 12 to 48 Vdc, current
from 5 A to 10 A |
|
CHT24V10A |
|
|
|
84 kb |
|
|
| |
|
|
|
|
|
|
|
|
|
| |
Switch mode battery chargers |
|
|
|
|
|
|
|
|
| |
Battery charger and power supply |
|
CC24V10A |
|
|
|
47 kb |
|
|
| |
|
|
|
|
|
|
|
|
|
 |
|
|
| |
 |
|
|
| |
Automatic
battery charger, CA24V5A |
Brochure - |
|
84 kb |
|
- Application:
Specific for diesel generators and emergency lighting.
- Power supply:
Voltage: 220 Vac ± 15% single-phase
Frequency: 45 to 65 Hz
- Output:
Nominal battery voltage: 24 V
Current: 5 A
Output voltage: 2.23 Vdc per lead acid cell, adjustable ±
15%
Regulation: better than 1%
|
|
|
 |
|
|
|
|
| |
 |
|
|
| |
Battery
chargers |
Folleto - |
|
42 kb |
|
- Application:
Power up to 1500 VA voltages
from 24 to 110 Vdc, without instrument.
- Power supply:
Voltage: 220 Vac ± 15%, 45 to 55 Hz single-phase
- Output:
Voltages according to the model and number of battery cells: 2.25
V per cell adjustable in 15%
Voltage regulation: better than 1%
Current regulation: better than 5%
|
|
|
|
 |
|
|
|
|
| |
 |
|
|
| |
Battery
charger |
Brochure - |
|
106 kb |
|
- Application:
Power up to 1500 VA voltages
from 24 to 110 Vdc, with instrument.
- Power supply:
Voltage: 220 Vac ± 15%, 45 to 55 Hz single-phase
- Output:
Voltage 2,23 Vdc per element, adjustable ± 15 %
Voltage regulation: < 1%
Current regulation: < 5%
- Instrument:
voltmeter for output voltage, class 2.
|
|
|
|
 |
|
|
|
|
| |
 |
|
|
| |
Battery
charger |
Folleto - |
|
67 kb |
|
- Application:
Power up to
1500 VA, voltages from 24 to 48 Vdc with selection switch for
high rate, instrument, alarms and several protections
- Power supply:
Voltage: 220 Vac ± 15%, 45 to 55 Hz single-phase
- Output:
Voltage 2.23 Vdc per element, adjustable ± 15 %
Voltage regulation: < 1%
Current regulation: < 5%
- Instrument:
voltmeter for output voltage.
|
|
|
|
 |
|
|
|
|
| |
|
|
| |
 |
|
|
| |
Power up to 1500 VA,
voltages from 24 to 110 Vdc, RCP48V30A |
Brochure - 25 kb |
|
- Function:
to maintain charged a storage battery bank.
- Power supply
voltage: 220 Vac ± 15%, 3 phases
Frequency: from 45 to 65 Hz
- Maximum output
voltage: 2.7 Vdc per element
Voltage adjustment range: 0 to 100%
Maximum output currents: 10, 20, 30, 40 A, according to the model
- Regulation of the adjusted values: < 1%
Ripple without accumulators: < 0.5 Veff
- Charge regimen:
manual or automatic
|
|
|
 |
|
|
|
|
| |
 |
|
|
| |
Power up to 5000 VA,
voltages from 24 to 220 Vdc, RCP48V60A |
Brochure - 76 kb |
|
- Function:
to maintain charged a storage battery bank.
- Power supply
voltage: 220 Vac ± 15%, 3 phases
Frequency: from 45 to 65 Hz
- Maximum output
voltage: 2.7 Vdc per element
Voltage adjustment range: 0 to 100%
Maximum output currents: 20, 30, 40, 50, 60 A, according to the
model
- Regulation of the adjusted values: < 1%
Ripple without batteries: < 0.5 Veff
- Charge regimen:
manual or automatic
|
|
|
 |
|
|
|
|
| |
 |
|
|
| |
Model
with 110 Vdc and 30 A nominal with alarm relay, RCP110V30AA1C |
Brochure - 103 kb |
|
- Function:
to convert alternating three-phase voltage into direct voltage
to charge a storage battery bank.
- Input:
Power supply voltage: 220 Vac ± 15%, 3 phases
Frequency: 45 to 65 Hz
- Output:
Nominal voltage: 110 V
Float, high rate and manual voltages adjustable from 0 to 150
Vdc
Nominal current: 30 A
Float and high rate currents: adjustable from 0 to 31 A
- Charge regimens:
float and high rate
|
|
|
|
 |
|
|
|
|
| |
 |
|
|
| |
CHT chargers series |
Brochure - 84 kb |
|
- Power supply:
Voltage: 220 Vac ± 10% single-phase
Frequency: 45 to 65 Hz
- Output:
Output voltage: 2.23 Vdc per element
Voltage regulation: < 1%
|
|
|
 |
|
|
|
|
| |
 |
|
|
| |
Switch mode battery charger CC24V10A |
Brochure - 47 kb |
|
-
Applications: battery charger for any type of batteries, emergency lighting, auxiliary power units, substations, PLC power supply, exchange branches and radio communications equipment.
-
Features:
AC/DC forward converter with PWM control at 50 kHz.
-
Power supply :
Voltage: 230 Vac ± 15%
Frequency: 50 / 60 Hz
-
Output:
Nominal voltage: 24 V
Nominal current: 10 A
Regulation: ± 1% in all the range
|
|
|
 |
|
|
|
|