ELECTRONIC CONTROLLERS

FOR ELEVATORS

HANDHELD TERMINAL T51FA

 

 

CONTROLES S.A.

Electrónica Industrial y Telecomunicaciones

Avenida Rivera 3314

11300 Montevideo

Uruguay

Tel.: +598 (2) 622 0651

Fax.: +598 (2) 622 2048

E-mail: info@controles.com

www.controles.com

 

GENERAL INFORMATION

T51FA is a useful tool for installation and maintenance people working with the CEA51FA family.

T51FA connects directly to a port in the controller and displays all the configuration parameters, logged events and counters. Some parameters can be changed by simple orders at the T51FA keyboard. This is particularly convenient to define operational time parameters when installing the controller or to modify accessibility options for user convenience.

NOTE: major changes at the installation site should be done using the configuration software CEA51FA-PCW running in a laptop PC, or else unskilled personnel can be instructed to take out of the socket the CEA51FA parameters memory (93LC66) and reinstall another one previously configured at the company’s engineering offices.

T51FA is a modified QTERM-J10 terminal from QSI Corp., 24 keys, EIA232 version, modified for TTL interfase. It connects directly to the TTL port at the CEA51FA. 5Vdc power supply is present at the port.

Dimensions

T51FA CONFIGURATION

T51FA parameters according to the specific needs are already loaded:

- auto wrap off

- auto scroll off

- auto line feed off

- cursor off

- power-on setup: only contrast adjust

To perform the Power-on Setup follow these steps:

- hold down ENTER key and connect the T51FA to the TTL port at the CEA51FA.

- keep the key pressed until the software version appears at the display.

- set the desired display contrast using the 1 (up) or 2 (down) keys. When the display is at a contrast you like, press the 3 (validate) key

DISPLAYING THE CEA51FA CONFIGURATION

Push 1 key. The display shows:

- controller model

- software version

- series number

- car number

- system identification

Push 2 key. The display shows:

- number of landings

- function (isolated, slave, master, external call

- operation (type of dispatch)

- rest station

- emergency station

- principal and secondary stations (only for master)

- position detection system

Push 3 key. The display shows:

- door type

- door state when resting

- door zone

- door delay

Push 4 key. The display shows the designation of the landings.

Push 5 key. The display shows the numeric code of each relay at the base card.

Push 6 key. The display shows the numeric code of each relay at the expansion card.

Push 7 key. The display shows the numeric code of each auxiliary relay, the total count of operations and the total time in operation.

Push 8 key. The display shows door selection for each landing.

Push 9 key. The display shows:

- releveling condition

- supervisory port

- code for digital indicators

- code for auxiliary outputs

Push 0 key. The display shows the call rejection state for the first landing. Each landing condition can be accessed and viewed pushing ­ (up) or ¯ (down) keys.

Push F1 key. The display shows the first timer. Each timer can be accessed and viewed pushing F1 (up) or F2 (down) keys. The following list shows the code for each timer and its meaning.

Code Meaning

TTRA travel time

TALA time to alarm with no manual safety

TBUZ tolerance to attendant

TWAI floor time

TFRE time to rest state

TAUH high speed auxiliary

TLOW time wait before going to the lowest landing

TDEL delayed stop

TDOO door operation

TCAR car passenger preference

TAUL low speed auxiliary

TAUX generic auxiliary

TSTA power start auxiliary

TCHI landing chime

TGEN dc generator

TINH auxiliary for position system 1.51

Push F4 key. The display shows:

LOL lowest landing

HIL highest landing

ADV advanced door-open (0/1: normal/advanced)

PSD door rest state at duplex principal station (0/1: open/closed)

SSD door rest state at duplex secondary station (0/1: open/closed)

DCT number of door-close trials

DOT number of door-open trials

DSS door safety switch (0/1: single/double switch)

FCC number of false car calls

CML number of accepted car calls at minimum load

FDO forced door-open (0/1: opens if call/opens always)

MODIFYING THE CONFIGURATION

When the display shows a timer its time definition can be changed pushing ­ or ¯ keys.

When the display shows the call rejection state for a landing:

- car call rejection state can be changed pushing > key

- down hall call rejection state can be changed pushing < key

- up hall call rejection state can be changed pushing , key

The changes are operational once entered, but they are not saved to the parameters memory.

To save all changes: push ENTER key. The controller will restart.

To quit without saving: push any 1 to 9 key or restart the controller.

RESTARTING THE CONTROLLER

Push DEL key to restart the system. The display shows:

CEA51FA Controller

Configurable

READING THE LIST OF EVENTS

Each event is shown in a single line, as follows:

- event index (1 to 50, 1 is the newest)

- event code (see table)

- car position at that time

Push F3 key. The display shows last registered event. Each event at the list can be accessed and viewed pushing ­ (up) or ¯ (down) keys. Four lines are shown at a time.

Event codes:

Code Description

TT Travel time between position detectors too long

MS Manual safety =0 for a time longer than TALA

MF Manual safety fails (goes to 0) while car is running

DC Door close failure

DO Door open failure

AF Automatic safety fails (goes to 0) while car is running

EX Upper and lower end flags are detected simultaneously

HT Motor temperature failure

PF Phase loss or phase reversal failure

CF Configuration fail :the controller is not properly configured

ST Start: power is applied to the controller

CC Configuration change

To erase the whole list that is being accessed push ENTER key. The display shows

No events